Sabre Page 1 of 10
Compulite R & D Lighting Specification
Compulite R & D, 3 Haroshet Street, New Industrial Zone, Ramat Hasharon 47279 Israel
Tel: 972-3-540-1268 Fax: 972-3-540-1276 Web: www.compulite.com
A. General
1. The lighting control console shall be microprocessor based and specifically
designed to provide complete lighting control of stage, studio, special events, and
permanent installation venues. The lighting control system shall be equal to a
Compulite Sabre lighting control console as manufactured by Compulite R & D. A
rack mounted component providing full tracking backup and a Remote control unit
shall also be available.
2. Flash EPROM shall be provided to permit onsite upgrades.
3. The control console shall include, but not be limited to the following. Systems that
do not provide the following features shall not be acceptable.
B. Quantities
1. The console shall provide direct control of up to 192 intelligent moving lights and
1,024 DMX 512 channels (255 channels shall be reserved for scrollers) and 1,024
dimmers.
2. More than 1,000 memories (cues) numbered from 0.1 to 999.9, 100 Q-Lists, 24
controllers with 99 pages (snaps) 999 Groups, 999 Macros, 999 Palettes, 999
Effects, 99 Position libraries, 99 Color libraries, 99 Gobo libraries, and 5 patches
shall be stored in internal non-volatile memory.
3. The total non-volatile internal memory capacity shall not be less than 2 MB. Show
files, Palette files, Effect files, and device files may be saved to an internal hard disk
or archived to a 3.5” formatted floppy disk. Industry standard Intel Pentium
microprocessors shall be standard.
C. Control Interface
1. The main controls shall consist of a numeric keypad, up to 20 pages of Numeric
Soft Keys working in 14 modes, 1 vertical wheel for dimmer and pan control. 1
vertical wheel for iris, tilt, and scroller frame control, 6 encoders with backlit LCD
displays for moving light parameter control and Effects attributes control, and a
sensitivity adjustable trackball for moving light pan and tilt positioning.
2. Two pairs of faders shall be definable as split Crossfaders or Crossfader and Rate
Fader.
3. 24 Controllers with 67-mm faders shall be provided. Each Controller shall be
provided with a bump button, assignment type/ chaser control keys. 3 LCD
selectable displays shall show assignments and controller status.
4. Two General Submasters shall master channels, spots, crossfaders, and controllers.
5. One General Master with blackout key shall be provided. The Channel Patch menu
shall provided an option to remove channels from General Master control.
6. Up to 3 high resolution monitors shall be provided for system status displays. One
of the monitors may be a Touch Screen. Additional monitors may be added on
remote interfaces connected via Ethernet.
7. An optional alphanumeric keyboard shall provide text labeling and an alternative
editing keyboard. The alphanumeric keyboard shall have multi-lingual support.